• CS-720 Timed Drainage Valve
  • CS-720 Timed Drainage Valve
  • CS-720 Timed Drainage Valve
  • CS-720 Timed Drainage Valve
  • CS-720 Timed Drainage Valve
  • CS-720 Timed Drainage Valve

CS-720 Timed Drainage Valve

Media: Water
Temperature: High Temperature
Actuator: Electric
Connection Form: Thread
Type: Pilot Operated
Material: Stainless Steel
Customization:
Gold Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
cs-720
Pressure
High Temperature
Valve Structure
Direct Action Diaphragm Structure
Power Supply
AC Solenoid Valve
Usage
Safety, Emptying, Drain, Temperature Control, Flow Control
Standard
GB
Application
Industrial Usage, Water Industrial Usage, Household Usage
Transport Package
Wooden Box
Specification
DN15-DN800
Trademark
XC
Origin
China
HS Code
8481804090
Production Capacity
9999

Product Description

 

CS-720 Timed Drainage ValveCS-720 Timed Drainage ValveCS-720 Timed Drainage ValveCS-720 Timed Drainage ValveFirst, product introduction:
A variety of interfaces available: G1/4, G3/8, G1/2
A variety of pressure options: 1.6Mpa, 2.5Mpa, 4.0Mpa, 8.0Mpa
Multipurpose voltage: 24~240AC/DC
Timing time: On 0.5~10s off 0.5~45min
Compact structure: size 110*50*87mm
 
2. Product use:
CS-720 timing drainage valve *** is suitable for compressor, cooler, separator, filter, gas storage tank, drip feet and other compressed air system components condensed water automatic discharge. The discharge time and interval time can be adjusted according to different needs.
Three, the main features:
1. The external leakage is blocked, the internal leakage is easy to control, and the use is safe. Internal and external leakage is an element that endangers safety. Other automatic control valves usually extend the stem, and the rotation or movement of the spool is controlled by the electric, pneumatic and hydraulic actuator. All these must solve the problem of external leakage of long-term action valve stem dynamic seal; *** Solenoid valve is an electromagnetic force acting on the iron core sealed in the magnetic insulation tube of the electric regulating valve, there is no dynamic seal, so the external leakage is easy to block. The torque control of the electric valve is not easy, it is easy to produce internal leakage, and even break the stem head; The structure of the solenoid valve is easy to control the internal leakage until it is reduced to zero. Therefore, the solenoid valve is particularly safe to use, especially suitable for corrosive, toxic or high and low temper-ature media.
2. The system is simple, it will connect to the computer, the price is low and modest. The solenoid valve itself is simple in structure and low in price. It is easy to install and maintain compared with other kinds of actuators such as regulating valves. More perfect is the composition of the automatic control system is much simpler, the price is much lower. Because the solenoid valve is a switch signal control, it is very convenient to connect with the industrial control computer. In today's computer popularity, the price has dropped significantly in the er-a, the solenoid valve is more obvious.
3. Fast action, small power, lightweight appearance. Solenoid valve response time can be as short as a few milliseconds, even pilot-oper-ated solenoid valve can be controlled in tens of milliseconds. Because of its own loop, it is more sensitive than other automatic control valves. Properly designed solenoid valve coil power consumption is very low, is energy-saving products; It can also be done only to trigger the action, automatically maintain the valve position, usually no power consumption. The solenoid valve is small in size, saving space, lightweight and beautiful.
4. The adjustment accuracy is limited, and the applicable medium is limited. Solenoid valve usually only switch two states, the spool can only be in two limit positions, can not be continuously adjusted, (trying to break through a lot of new ideas, but are still in the test stage) so the adjustment accuracy is still limited.
5. Solenoid valve has higher requirements for the cleanliness of the medium, including granular media can not be applied, such as impurities must be filtered first. In addition, the viscous medium can not be applied, and the medium viscosity range for specific products is relatively narrow.
6. Variety of models, use ***. Although the solenoid valve has congenital shortcomings, the advantages are still very prominent, so it is designed into a variety of products to meet a variety of different needs, the use is very good. The progress of solenoid valve technology is also centered on how to overcome congenital deficiencies and how to better play the inherent advantages.