Edrv Dynamic Balance Electric Regulating Valve

Temperature: Ordinary Temperature
Certification: GS
Media: Gas, Oil, Water, Acid
Standard: Standard
Connection Mode: Flange
Power: Manual
Customization:
Gold Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
EDRV
Material
Stainless Steel
Type
Self-Operated
Use
Adjust
Pressure
Normal Pressure
Port of Ningbo
Class IV (Standard, Metal Seat)
Body Type
Straight Through, Angle, Z Shape
Transport Package
Wooden Box
Specification
DN15-DN500
Trademark
xc
Origin
China
HS Code
8481804090
Production Capacity
10000

Product Description




Edrv Dynamic Balance Electric Regulating ValveEdrv Dynamic Balance Electric Regulating ValveEdrv Dynamic Balance Electric Regulating ValveEdrv Dynamic Balance Electric Regulating ValveEDRV series dynamic balance electric regulating valve reliable quality, reasonable price, perfect after-sales service. "Electric dynamic balance valve" is suitable for various light and heavy industries and building pipelines. [Balance valve/central air conditioning end control valve] widely used in: chemical, petrochemical, petroleum, paper, mining, power, liquefied gas, food, pharmaceutical, water supply and drainage, municipal, mechanical equipment supporting, electronic industry, urban construction and other fields.
Electric control valve characteristics
[Balance valve/control valve] the principle is the anti-regulation in the valve body, when the pressure at the entrance increases, the diameter is automatically reduced to reduce the change of flow rate, and vice versa. If the reverse adjustment, this adjustment system does not work. And the valve plate that plays the regulating role is directional, and the reverse pressure can even reduce or even close the flow. Since the balancing valve is installed for better heating, there is no problem of reverse installation. If it is reverse installation, it is a human error, and of course it will be corrected. The balance valve belongs to the regulating valve category, its working principle is to change the gap between the valve core and the seat (that is, the opening), change the flow resistance of the fluid flowing through the valve, to achieve the purpose of regulating the flow rate.

EDRV series electric regulating valve working principle


Dynamic balance and electric regulating valve integration products. Its working principle is shown in Figure 1, in the variable flow system with large fluctuations in system load, when the system pressure changes, the differential pressure (P1-P3) at the two ends of the dynamic balance electric regulating valve also changes:
Electric regulating valve schematic description:
(1) When the import pressure P1 rises, (P1-P2) increases, then the electric valve spool moves upward, so that the opening between P1 and P2 is reduced, and the spool pressure P2 is reduced; When the import pressure P1 is reduced, (P1-P2) is reduced, then the electric valve spool downward movement, so that the opening between P1 and P2 is increased, and the spool pressure P2 is increased. Therefore, no matter how the pressure of the system changes, through the adjustment of the electric valve spool, the pressure difference between P2 and P3 always remains unchanged. Therefore, the dynamic valve has strong anti-interference ability and dynamic balance function; (2) When the direct stroke electric actuator accepts the control signal to make the valve shaft extend A-B up and down (or the Angle stroke electric actuator accepts the control signal to make the valve shaft extend R to rotate), the opening between P2 and P3 also changes. Because no matter how the system pressure difference (P1-P3) changes, the pressure difference between P2 and P3 (P2-P3) is always the same, so corresponding to any opening position, the water flow rate is certain, and the actual flow characteristic curve of the electric control valve is consistent with its ideal flow characteristic curve, without deviation. Therefore, this kind of electric regulating valve has better regulating characteristics than the traditional electric regulating valve.

EDRV series electric regulating valve main parts material

 
Valve body Nodular cast iron Electric actuator housing Aluminum alloy
Valve sleeve Stainless steel Spool Orichalcum

Technical parameters of EDRV series electric regulating valves

 
Product model Valve form Specifications Differential pressure range
(KPa)
Flow range
(m0/h)
Work
Stress
Flow
Error
Fluid
Temperature
A/D-EDRV1 two-way DN25 30-300. 0.2-2.9 PN16 5% 0-100 ºC
A/D-EDRV2 DN32 30-300. 0.5-4-7        
A/D-EDRV3 DN40 30-300. The 1-7-7        
A/D-EDRV4 DN50 30-300. 2-12.1        
A/D-EDRV8 DN65 30-300. 3-20.4 -        
A/D-EDRV9 DN80 30-300. 5-30.8 -        
A/D-EDRV10 DN1OO 30-300. 10-45.3 -        
A/D-EDRV11 DN125 30-300. 15-70-7        
A/D-EDRV12 DN150 30-300. 20-101.8        
A/D-EDRV13 DN200 33-300. 5.0-360.        
A/D-EDRV14 DN250 22-210. 4.O-460        

EDRV series electric regulating valve mounting size

 

Mounting dimension

Product model number Valve form Specifications Outline and mounting dimensions (mm)        
L H1 H2 D (φ) flange G thread      
A/D-EDRV1 Bipass
Wire orifice
DN25 160 265 70   G1
A/D-EDRV2 DN32 180 275 70   G1-1/4  
A/D-EDRV3 DN40 300 290 90   G1-1/2  
A/D-EDRV4 DN50 300 290 90   G2  
A/D-EDRV5 Bipass
Flange
DN32 160 220 70 1OO  
A/D-EDRV6 DN40 200 235 110 110    
A/D-EDRV7 DN50 215 230 115 125    
A/D-EDRV8 DN65 230 238 120 145    
A/D-EDRV9 DN80 275 275 146 160    
A/D-EDRV10 DNl00 290 295 165 180    
A/D-EDRV11 DNl25 315 307 208 21O    
A/D-EDRV12 DNl50 350 326 205 240    
A/D-EDRV13 DN200 430 715 295 295    
A/D-EDRV14 DN250 520 740 345 355    

 

Edrv Dynamic Balance Electric Regulating ValveEdrv Dynamic Balance Electric Regulating ValveEdrv Dynamic Balance Electric Regulating ValveEdrv Dynamic Balance Electric Regulating ValveEdrv Dynamic Balance Electric Regulating ValveEdrv Dynamic Balance Electric Regulating Valve