• Zcrb Electromagnetic Emergency Shutdown Valve
  • Zcrb Electromagnetic Emergency Shutdown Valve
  • Zcrb Electromagnetic Emergency Shutdown Valve
  • Zcrb Electromagnetic Emergency Shutdown Valve
  • Zcrb Electromagnetic Emergency Shutdown Valve
  • Zcrb Electromagnetic Emergency Shutdown Valve

Zcrb Electromagnetic Emergency Shutdown Valve

Media: Water
Temperature: High Temperature
Actuator: Electric
Connection Form: Thread
Type: Pilot Operated
Material: Stainless Steel
Customization:
Gold Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
ZCRB
Pressure
High Temperature
Valve Structure
Direct Action Diaphragm Structure
Power Supply
AC Solenoid Valve
Usage
Safety, Emptying, Drain, Temperature Control, Flow Control
Standard
GB
Application
Industrial Usage, Water Industrial Usage, Household Usage
Transport Package
Wooden Box
Specification
DN15-DN800
Trademark
XC
Origin
China
HS Code
8481804090
Production Capacity
9999

Product Description

 

 

Zcrb Electromagnetic Emergency Shutdown ValveZcrb Electromagnetic Emergency Shutdown ValveZcrb Electromagnetic Emergency Shutdown ValveZcrb Electromagnetic Emergency Shutdown Valve

ZCRB electromagnetic emergency shutdown valve

ZCR series normally open electromagnetic emergency cut off valve is a new type of gas pipeline engineering safety equipment.

The details of

Details of ZCRB electromagnetic emergency shut-off valve:
 
Product name: ZCRB series normally open electromagnetic emergency cut off valve
Product model: ZCRB
ZCRB series normally open electromagnetic emergency cut-off valve product introduction:
ZCR series normally open electromagnetic emergency cut off valve is a new type of gas pipeline engineering safety equipment, the main applications are as follows:
1. It is connected with combustible gas leakage monitoring instrument. When the instrument detects the flammable gas leak, it automatically and quickly closes the main gas valve, cuts off the gas supply, and stops the occurrence of malignant accidents in time.
2. ZCR series normally open electromagnetic emergency cut off valve is connected with the limit temperature (or pressure) safety controller of thermal equipment. When the temperature or pressure of the detection point in the equipment exceeds the set limit value, the gas supply valve is automatically and quickly closed to stop the fuel supply.
3. ZCR series normally open electromagnetic emergency cut-off valve is connected with the central fire alarm system of high-rise buildings. When there is a crisis in the building, the gas supply in the building is automatically cut off to prevent the occurrence of gas explosion.
4, in the city or factory gas supply network set up ZCR gas emergency cut off valve, can be centralized control in the central control room, remote control, emergency close the accident site of the pipeline supply.
ZCRB series normally open electromagnetic emergency cut off valve technical parameters
Product structure: direct acting
Nominal pressure: 1.6MPa
Working pressure difference: 0~0.05MPa
ZCR series normally open electromagnetic emergency cut-off valve working medium: gas, natural gas, liquefied petroleum gas and other non-corrosive gas liquid
Closing time: <1 second
Medium temperature: -15ºC~60ºC
Opening mode: manual reset or electric reset
Power supply voltage: AC220VA, DC24V, DC12V
ZCR series normally open electromagnetic emergency cut-off valve full grade: ordinary Ex type
ZCR series normally open electromagnetic emergency cut off valve control mode: uninterrupted output or pulse electromagnetic force
ZCRB series normally open electromagnetic emergency cut off valve inner thread connection size
DN G L H
25 1 90 130
32 1 1/4 140 150
40 1 1/2 156 170
50 2 180 190
ZCRB series normally open electromagnetic emergency cut-off valve flange connection dimensions
DN D1 K D b f n-d L H
25 5 85 115 16 3 4 -? 14 160 180
32 6 100 140 18 3 4 -? 18 180 195
40 84 110 150 18 3 4 -? 18 200 05
50 9 125 165 20 3 4 -? 18 230 220
65 118 145 185 20 3 4 -? 18 290 245
80 132 160 200 20 3 8 -? 18 310  
100 156 180 220 22 3 8 -? 18 350  
125 184 210 250 22 3 8 -? 18 400  
150 211 240 285 24 3 8 -? 22 480  
200 266 295 340 24 3 12 -? 22 495  
250 319 355 405 26 3 12 -? 26 622  
300 370 410 460 28 4 12 -? 26 698  
350 429 70 520 30 4 16 -? 26 787  
400 480 525 580 32 4 16 -? 30 914  
450 548 585 640 34 4 20 -? 30 978  
500 609 650 715 36 4 20 -? 33 978  
600 720 770 840 38 5 20 -? 36 1295  
Zcrb Electromagnetic Emergency Shutdown ValveZcrb Electromagnetic Emergency Shutdown ValveZcrb Electromagnetic Emergency Shutdown ValveZcrb Electromagnetic Emergency Shutdown ValveZcrb Electromagnetic Emergency Shutdown ValveZcrb Electromagnetic Emergency Shutdown Valve
Zcrb Electromagnetic Emergency Shutdown Valve

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.