Media: Water
Temperature: High Temperature
Actuator: Electric
Connection Form: Thread
Type: Pilot Operated
Material: Stainless Steel
Customization:
Gold Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
ZCS
Pressure
High Temperature
Valve Structure
Direct Action Diaphragm Structure
Power Supply
AC Solenoid Valve
Usage
Safety, Emptying, Drain, Temperature Control, Flow Control
Standard
GB
Application
Industrial Usage, Water Industrial Usage, Household Usage
Transport Package
Wooden Box
Specification
DN15-DN800
Trademark
XC
Origin
China
HS Code
8481804090
Production Capacity
9999

Product Description

 


Zcs Water Solenoid Valve, Air Solenoid ValveZcs Water Solenoid Valve, Air Solenoid ValveZcs Water Solenoid Valve, Air Solenoid ValveZcs Water Solenoid Valve, Air Solenoid Valve

Product description

ZCS (DF) series air solenoid valve, water solenoid valve application range:
It is a common pipeline switch element in clean water automatic control system, and is widely used in printing and dyeing, clean water, power plant, petroleum, chemical industry, metallurgy, textile, food, shipbuilding, medical, environmental protection, urban and other industries and departments of clean water transmission pipeline system to complete the automatic control of the medium. It is the ideal choice to realize the automatic control of clean water transmission pipeline.
Water solenoid valve model: ZCS Water solenoid valve diameter: 50MM-400MM Water solenoid valve use pressure: 0.8MPA-1.6MPA
Connection mode of water solenoid valve: flange connection Water with solenoid valve operation form: solenoid coil power Water with solenoid valve main function: switch function
Water solenoid valve use medium: water industry pipeline Water solenoid valve material: stainless steel Water solenoid valve standard: mechanical ministry standard or custom non-standard

ZCS air solenoid valve, water solenoid valve working principle:
Diameter 15 ~ 100 for the diaphragm type pilot solenoid valve for the secondary opening valve, diameter 125 ~ 300 for the three times the pilot solenoid valve, its structure is mainly composed of secondary valve and main valve.
The solenoid valve for water can be divided into normally closed solenoid valve and normally open solenoid valve according to the different switching state when the power is off. Normally closed solenoid valve, normal position, the active iron core seals the secondary valve port, the pressure in the valve chamber is balanced, the secondary valve and the main valve port are closed. When the coil is energized, the electromagnetic force will be drawn on the active iron core, the auxiliary valve is opened, and the medium self-guiding valve in the main valve chamber leaks out, so that the pressure difference between the main valve cup and the upper and lower parts of the valve is generated, the diaphragm or the valve cup is quickly lifted, the main valve port is opened, and the valve is in a path state. When the coil is powered off, the magnetic field disappears, the active iron core is reset, the secondary closure is closed, and the pressure in the secondary valve and the main valve cup rises, the main valve cup is pressed to the seat, and the valve is closed. Normally open solenoid valve, when the coil is energized, the magnetic force is generated, the armature moves down under the magnetic force, pushing the auxiliary valve cup down, the auxiliary valve is closed, with the main valve cup upward and downward pressure difference trend equal, the main valve cup from the pressure to the sealing surface, the valve is closed. When the coil is powered off, the magnetic force is zero, the armature and the auxiliary valve cup rise due to the action of the spring, the auxiliary valve opens, the medium in the main valve cup flows away through the auxiliary valve, the pressure drops, when the pressure drops to a certain value, the main valve cup rises upward from the upper and lower pressure difference, the main valve opens, the valve opens.
Air solenoid valve, water solenoid valve installation size:
Nominal diameter DN Internal threaded connection Flange connections
Overall dimensions Internal thread Overall dimensions Flange dimensions
H L G H L D D1 D2 n-d b f
15 112 80 1/2                
20 119 80 Three quarters of                
25 130 90 1 130 160 115 85 65 From 4-14 16 3
32 137 140 1 1/4 137 180 140 100 76 From 4 to 18 18 3
40 152 156 1 1/2 152 200 150 110 84 From 4 to 18 18 3
50 164 180 2 164 230 165 125 99 From 4 to 18 20 3
65       222 290 185 145 118 From 4 to 18 20 3
80       253 310 200 160 132 Phi 8 to 18 22 3
100       260 350 220 180 156 Phi 8 to 18 24 3
125       315 400 250 210 184 Phi 8 to 18 26 3
150       350 480 285 240 211 Phi 8-22 26 3
200       390 600 340 295 266 Phi 8-22 26 3
250       430 730 395 350 319 Phi 12-22 28 3
300       480 850 445 400 370 Phi 12-22 28 4
350       605 980 505 460 429 From 16-23 30 4


Zcs Water Solenoid Valve, Air Solenoid ValveZcs Water Solenoid Valve, Air Solenoid ValveZcs Water Solenoid Valve, Air Solenoid ValveZcs Water Solenoid Valve, Air Solenoid ValveZcs Water Solenoid Valve, Air Solenoid ValveZcs Water Solenoid Valve, Air Solenoid Valve
Zcs Water Solenoid Valve, Air Solenoid Valve

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now